AC 169-6

Product: CUMMINS Alternator: UCI 274 E - 60Hz Control System: DSE 6020
INTRODUCTION
Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.
 
Certificate
  TS ISO 8528
  CE
  SZUTEST
  2000/14/EC
General Characteristics
Model Name AC 169-6
Frequency (Hz) 60
Fuel Type Diesel
Engine Made and Model CUMMINS - 6BTAA 5,9-G6 - 60Hz
Alternator Made and Model Stamford - UCI 274 E - 60Hz
Control Panel Model DSE 6020
Canopy MS 60
3 Phase, 60 Hz, PF 0.8
Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper
kVA kW kVA kW
480/277 169 135.20 154 123.20 203.28
380/220 161 128.80 146 116.80 244.62
208/120 169 135.20 154 123.20 469.11
STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed.

PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation.
ENGINE SPECIFICATIONS
Engine CUMMINS
Engine Model 6BTAA 5,9-G6 - 60Hz
NO. OF CYLINDERS AND BUILD 6 cylinders - in line
BORE AND STROKE mm 102 X 120
TOTAL DISPLACEMENT L 5.9
Aspiration Turbo Charged and AfterCooled
COMPRESSION RATIO 16.5:1
RATED SPEED (RPM) d/dk 1800
OIL CAPACITY L 16.4
Standby Power (kW/HP) 160/215
Block Heater QTY
1
Block Heater Power (Watt) 1000
Fuel Type
Diesel
Injection Type and System
Direct
Type of Fuel Pump
Bosch Rotary Type
Governor System
Electronic
Operating Voltage (Vdc)
12 Vdc
Battery and Capacity (Qty/Ah) 1x85
Charge Alternator (A)
55
Cooling Method
Water Cooled
Cooling Fan Air Flow (m3/min) 162
Coolant Capacity (engine only / with radiator) (lt) 9.1/21.4
Air Filter
Dry Type
Fuel Cons. Prime With %100 Load (lt/hr) 39
Fuel Cons. Prime With %75 Load (lt/hr) 31
Fuel Cons. Prime With %50 Load (lt/hr) 21
ALTERNATOR SPECIFICATIONS
Manufacturer Stamford
Alternator Made and Model UCI 274 E - 60Hz
Frequency (Hz) Hz 60
Power (kVA) kVA 146
Design   4 Pole,  Brushless
Voltage V 380
Phase 3
A.V.R. AS440
Voltage Regulation (+/-) 1
Insulation System H
Rated Power Factor 0.8
WEIGHT COMP. GENERATOR (Kg) 492
COOLING AIR (m³/min) m3 37
SIZE and WEIGHT
Open Type DRY WEIGHT (kg.)
(kg.)
LENGTH
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
2750 1300 1751 470
CANOPY DRY WEIGHT (kg.)
(kg.)
LENGTH
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
MS 60
2240 3934 1356 2156 470
STANDARD SPECIFICATIONS
Water cooled, Diesel engine Radiator with mechanical fan Protective grille for rotating and hot parts Electric starter and charge alternator Starting battery (with lead acid) including rack and cables Engine coolant heater Base frame design incorporates an integral fuel tank and anti-vibration isolators Flexible fuel connection hoses Single bearing, class H alternator Industrial exhaust silencer and steel bellows supplied separately(for open sets) Static battery charger Manual for application and installation
OPTIONAL EQUIPMENTS
TRANSFER SWITCH
- Three or four pole motor operated circuit breaker
- Four Pole Contactor
- Three Pole Contactor
OTHER ACCESSORIES
- Supplied with oil and coolant - 30 °C
- Tool kit for maintenance
- Trailer
- Automatic transfer switch
- Main Fuel Tank
- Battery isolating switch
- Inlet and outlet acoustic baffles
- Low and high fuel level alarm
- Electrical oil drain pump
- Automatic or manual fuel filling system
- Duct adapter ( on radiator)
- Enclosure: weater protective or sound attenuated
- Residential silencer
CONTROL SYSTEM
- Remote communication with modem
- Alarm output relays
- Charge Ammeter
- Earth fault, single set
- Remote relay output
- Paralel system with mains.
- Automatic synchronising and power control system ( multi gen-set
Parallel )
- Remote annunciator panel
- Transition synchronization with mains
ENGINE
- Oil heater
- Low water level alarm
- Fuel-Water Seperator Filter
ALTERNATOR
- PMG excitation + AVR
- Main line circuit breaker
- Anti-Condensation Heater
- Over sized alternator
 
Control System: DSE 6020
1. Main status display. 
2. Display scroll button. 
3. Page(information) button. 
4. Common alarm indicator. 
5. Status LED's. 
6. Operation selecting buttons.
Devices
●DSE, model 6020 Auto Mains Failure control module.
●Battery charger input 198-264 volt, output 27,6 V 5 A (24 V) or 13,8 Volt 5A (12V)
●Emergency stop push button and fuses for control circuits.
CONSTRUCTION and FINISH
●Components installed in sheet steel enclosure. Phosphate chemical, pre-coating of steel provides corrosion resistant surface. Polyester composite powder topcoat forms high gloss and extremely durable finish. Lockable and hinged panel door provides easy access to components.
INSTALLATION
Control panel is mounted on baseframe with steel stand. Located at the right side of the generator set (When you look at the Gen.Set. from Alternator)
GENERATING SET CONTROL UNIT
The DSE 6020 is a standard control module for our generator sets up to 200kVA and ıt has been designed to start and stop diesel and gas generator sets.
The DSE 6020 module has been designed to monitor generator frequency, volt, current, engine oil pressure, coolant temperature running hours and battery volts.
Module monitors the mains supply and switch over to the generator when the mains power fails.
The DSE6020 also indicates operational status and fault conditions, Automatically shutting down the Gen. Set and giving true first up fault condition of Gen. Set failure.The LCD display indicates the fault.

STANDARD SPECIFICATIONS
●Microprocessor controlled.
●LCD display makes information easy to read.
●4-line, 64 x 132 pixel display.
●Automatically transfers between mains (utilty) and generator power.
●Manual programming on front panel.
●User-friendly set-up and button layout.
●Remote start.
●Event logging (5)showing date and time.
●Controls: Stop/Reset, Manual, Auto, Test, Start, buttons. An additional push button next to the LCD display is used to scroll through the modules' metering displays.

Instruments
ENGINE
●Engine speed.
●Oil pressure.
●Coolant temperature.
●Run time.
●Battery volts.
●Configurable timing.

GENERATOR
●Voltage (L-L, L-N).
●Current (L1-L2-L3).
●Frequency.

MAINS
●Voltage (L-L, L-N).
●Frequency.
●Mains ready.
●Mains enabled.
●Gen. Set ready.
●Gen. Set enabled.
Protection Circuits
WARNING 
●Charge failure. 
●Battery Low/High voltage. 
●Fail to stop. 
●Low /High generator voltage. 
●Under/over generator frequency. 
●Over /Under speed. 
●Low oil pressure. 
●High coolant temperature. 

SHUT DOWNS 
●Fail to start. ●Emergency stop. 
●Low oil pressure. 
●High coolant temperature. 
●Over /Under speed. 
●Under/over generator frequency. 
●Under/over generator voltage. 
●Oil pressure sensor open. 
●Coolant temperature sensor open. 

ELECTRICAL TRIP 
●Generator over current.


Options
●Flexible sensor can be controlled with temperature, pressure, percentage (warning/shutdown/electrical trip)
●Local setting parameters and monitoring from PC to control module with USB connection (max 6 mt).
Standards
Elecrical Safety / EMC compatibility
●BS EN 60950 Electrical business equipment.
●BS EN 61000-6-2 EMC immunity standard.
●BS EN 61000-6-4 EMC emission standard
STATIC BATTERY CHARGER
● Battery charger is manufactured with switching-mode and SMD technology and ıt has high efficiency.
Battery charger models' output V-I characteristic is very close to square and output is 5 amper, 13,8 V for 12 volt and 27,6 V for 24 V . Input 198 - 264 volt AC.
Proline 2405 has fully output shot circuit protection and ıt can be used as a current source.
Proline 1205/2405 charger has high efficiency, long life, low failure rate, light weight and low heat radiated in accordance with linear alternatives.
The charger is fitted with a protection diode across the output.
Connect charge fail relay coil between positive output and CF output.
They are equipped with RFI filter to reduce electrical noise radiated from the device.
Galvanically isolated input and output typically 4kV for high reliability.
Canopy: MS 60
1. Steel structures. 
2. Emergency stop push button. 
3. Control panel is mounted on the baseframe . Located at the right side of the generator set. 
4. Corrosion-resistant locks and hinges. 
5. Oil could be drained via valve and a hose 
6. Exhaust system in the canopy. 
7. Special large access doors for easy maintanance 
8. In front and back side special large access doors for easy maintanance 
9. Base frame -fuel tank. 
10. Lifting points similar to ISO container , located on each top corner of the canopy. 
11. The cap on the canopy provides easy accsess to radiator cap. 
12. Sound proofing materials 
13. Plastic air intake pockets.
INTRODUCTION
Sound-attenuated and weather protective enclosures for generating sets from Aksa, meet event the sound requirements and provide optimum protection from inclement weather and development by our specialist acoustic engineers. Our modular designed sound insulated canopies provide ease of access for servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed to optimize genset cooling performance, providing you with confidence that genset ratings and ambient capability.
STANDARD SPECIFICATIONS
Compact footprint, low profile design. 
Enclosure, generator set, exhaust system and fuel tank are pre-ssembled, pre-integrated and shipped as one package 
Body made from steel components treated with polyester powder coating 
Fire retardant foam insulation 
Easy access to all service points 
Exhaust system inside canopy 
Large doors on each side 
Control panel viewing window in a lockable access door 
Emergency stop push button mounted on enclosure exterior 
Cooling fan and battery charging alternator fully guarded 
Fuel fill and battery can only be reached via lockable access doors. 
Lifting points on the top of canopy and base frame 
Customer options available to meet your applications needs. 
Aksa makes its generating sets' noise level tests in accordance with directive 2000/14/EC validation of the noise level test has been aproved by the notified body Szutest

CANOPY MODEL MS 60
WIDTH mm. 1356
LENGTH mm. 3934
HEIGHT mm. 2156
TANK CAPACITY (lt.) Lt. 470